Click
Here For Print Friendly PDF Version |
| |
|
| |
 |
High
Capacity
Line Leak Detector |
|
|
Flow rates over 200 GPM • Application: 3 & 5
Horsepower Submersible Pumps |
| |
|
|
|
|
|
| |
|
|
● |
Any Fuel* |
| |
-
Alcohols, Biodiesel, Aviation, |
| |
- Gasoline, Diesel |
|
● |
Any Pump |
|
● |
Any
Pipeline System |
|
● |
Integrated
Check Valve / Pressure Relief |
|
● |
Combined
Rigid and Flexible Pipe |
| |
- Certification up to 502 gallons |
|
● |
Rigid Pipe
only |
| |
-
Certification up to 406 gallons |
|
● |
Smallest
profile |
|
● |
24 month
warranty |
|
● |
Now
Available! Factory Certifications
|
| |
for
Installation and Annual Testing** |
|
● |
Field
Adjustable Leak Threshold |
| |
|
|
|
Press image for
larger view |
|
|
|
|
|
|
|
New Certification Applicable With Any Pipe
Configuration: Largest volume
/ longest line and now Certified for combination of rigid and
flexible pipe up to 502 gallons.
The 99 LD-3000 is certified for the
following pipe: 1171 feet of 3" I.D. rigid pipe, up to 406
gallons; 260 feet of 3" I.D. flexible pipe, up to 96 gallons;
1431 feet combination of rigid and flexible pipe, up to 502
gallons. |
|
|
|
Longest Guarantee:
The 99 LD-3000 series shares
the longest guarantee available in the industry with the
VmI
99 LD-2000 and 99 LD 2200
series leak detectors. For 24 months after installation, the 99
LD-3000 is guaranteed to see a 3 GPH @ 10 PSI leak. |
|
|
|
Now With Quick Purge Line Feature:
At installation, the 99
LD-3000 is open, ready to purge the line system. After line is
purged, one screw is removed to enable leak detection function. |
|
|
|
Electronic Line Leak Detection Upgrade!
The 99 LD-3000 may be upgraded in the field to eliminate
thermal induced slow-flow, provide submersible shut-down, and
alarm notification to site monitoring equipment. Request
information on the ISM-4080, an easy upgrade for existing
or new installations. The ISM-4080 also stages turbines
and controls solenoid valves for loading racks and marine
applications. If there is no need for staged turbines, solenoid
valve control, alarm notification or submersible shut-down,
request information on the ARM-4073 to eliminate false
alarms only. |
| |
|
Field Adjustable Leak Threshold:
All
VmI
mechanical line leak detectors have been factory assembled and
tested to meet the EPA leak detection threshold established
during certification testing. Abnormal field conditions such as
high line resiliency (high bleed-back), pump pressures over 40
PSI and high head pressures affect line leak detection
sensitivity. Additionally, wear affects performance of leak
detection over time. To meet these issues,
VmI
established through certification testing, the ability of field
technicians to adjust
VmI
mlld’s to compensate for field variables and normal wear. Please
read Technical Bulletin 032805 for specific instructions on this
feature. |
| |
|
*See Technical
Specifications Below
**Contact factory for details |
|
U.S. Patent No. 4,966,190 • Designed and Manufactured in U.S.A. |
|
|
| |
|
Easy Installation!
The 3" inlet of the 99
LD-3000 allows the leak detector to be installed in the
discharge port of 3 - 5 HP submersible pumps. The
discharge of the 99 LD-3000 is 3" male thread; Height - 16.25
inches. Width - 7.86 inches. Weight - 29 pounds; Can be
installed by one person. Now with easy access to check valve for
field replacement. The 99 LD-3000 is available with flange
fittings instead of threads as Part # 99 LD-3000\FL. |
| |
|
Integrated In-Line Check Valve / Pressure
Relief: Allows the leak
detector to compensate for a defective submersible pump pressure
relief or check valves that allow drain-back into tanks. The
integrated pressure relief valve of the 99 LD-3000 will hold 30
PSI in the line by itself. |
| |
|
One Way Poppet Flow Path!
Isolates pump turbulence from line leak detection at pump
start-up. The hardened stainless steel poppet does not
dimensionally change due to thermal conditions encountered
during station operation (precision metering change is
insignificant down to -20 degrees F). |
| |
|
Reverse Ratio Piston / Poppet Combination:
The leak detector has a smaller diameter piston area than the
poppet it is attached to. This allows the leak detector to stay
in the fast fill position (3 GPM) to a higher pressure while
compressing vapor pockets and stretching flexible line faster,
resulting in less time to full flow. |
| |
|
Smaller Volume / Faster Response Piston Size:
Results in one-fourth the volume of fuel to replace when in leak search and
one-fourth the volume to return to the line when pump is turned off. This
results in achieving faster full flow to dispensers and faster resets to detect
leaks. |
|
|
Technical Specifications 99 LD-3000 |
|
|
|
Fuels: |
|
|
|
|
● |
Gasoline, 100% methanol*,
100% ethanol*, up to 15% MTBE |
|
|
● |
Any combination of the above |
|
|
● |
#1 or #2 diesel, kerosene,
Jet A* or JP-4*, AV Gas* |
|
|
|
and Biodiesel* (all blends). |
| |
|
|
| |
* |
When
used with Biodiesel, any alcohol fuel
concentration above 20%, Jet
A, JP-4, or AV Gas, order part # LD3-SSVS
for stainless steel fittings and stainless steel
vent tubing.
For chemical applications other than those
listed above, contact factory. |
| |
|
Certified to meet EPA 3 GPH @
10 PSI: |
| |
|
|
| |
● |
Rigid pipe up to 406 gal., 1171 ft. of 3" id. |
| |
● |
Flexible pipe up to 96 gal.,
260 ft. of 3" id. |
| |
● |
Combination of Rigid and Flexible pipe up to 502
gal., |
| |
|
1431 ft. of 3" id. |
| |
|
|
|
Construction:
Forged
steel body; Steel alloy; Forged steel threads. |
| |
|
|
|
Cylinder Assembly:
Anodized 6061-T6 Aluminum |
|
|
|
|
|
Internal Parts: |
Anodized 2011-T3
Aluminum, 6061-T6 Aluminum;
Acetron GP;
CDSM 1026 and DOM 1026 steel;
17-4 stainless steel |
|
|
|
|
|
|
|
|
Seals:
Low drag, stainless steel spring energized
teflon seals |
|
|
|
|
Press Image for Larger View
|
|
O Rings:
U.L. Approved V9702-Viton Type B
Fluorocarbon |
|
|
|
Metering Pin and Poppet:
17-4 stainless steel |
|
|
|
Check Valve:
Acetron GP, Viton F Seal |
|
|
|
Pressure Relief: |
Stainless Steel, 29 PSI pressure
relief. This pressure is in addition to the pump
pressure relief. |
|
|
|
|
Inlet:
3" male
Outlet:
3" male |
|
|
|
|
|
|
● |
Certified to handle 12+ feet of head
pressure. |
| |
● |
Exceeds EPA specifications
for 3 GPH @ 10 PSI hourly test. |
|
●
|
Vent line must be
unobstructed, leak tight and connected to headspace of
tank, not to be subjected
to pressure or vacuum. |
| |
● |
Combination
line check/pressure relief prevents drainage into the
tank. |
| |
|
|
| |
|
Click