Longest Guarantee |
|
The 99 LD-2200 shares the longest guarantee
available in the industry, along with the
Vmι
99 LD-2000 and 99 LD-3000 leak detectors. For 24 months after
installation, the 99 LD-2200 is guaranteed to see a 3 GPH @ 10
PSI leak. |
| |
|
Highest Flow Capacity |
|
If you can pump it, we can flow it! The 99
LD-2200 has maximized the flow and flow path. This new design
reduces turbulent flow, maximizing pump performance for any pump
housing. |
| |
|
One-Way Poppet Flow Path |
|
The 99 LD-2200 shares this newest technology
with the 99 LD-2000. The One-Way Poppet Flow Path
isolates pump turbulence from line leak detection at pump
start-up. Hardened Stainless Steel poppet does not dimensionally
change due to thermal conditions encountered during normal
station operations. |
| |
|
Reverse Ratio Piston / Poppet Combination |
|
Reverse Ratio means the leak detector has a
smaller diameter piston area than the poppet it is attached to.
This smaller piston area keeps the leak detector in the fast
fill position (3 GPM) to a higher pressure while compressing
vapor pockets and expanding flexible pipe.
This means less time to full flow! Another benefit of the
Reverse Ratio Piston / Poppet Combination is faster reset with
the pump off. The leak detector does not have to completely
reset (as with competitive leak detectors) for the poppet to be
forced into the reset mode at pump start-up. |
| |
|
Smaller Volume / Faster Response Piston Size |
|
With a reduced piston size, there is one-fourth the volume to
replace when in leak search and one-fourth the volume to return to the line when
the pump turns off. This combination makes for a more responsive and faster leak
detector. Less volume to leave the line for the leak detector to reset and catch
leaks. Less volume to fill and provide full flow for dispensing! |
|
|
|
Superior Flex-Pipe Performance |
|
The reduced surface area of the piston significantly reduces
the surface area exposed to hydraulic line shock. This results in enhanced
performance in steel and fiberglass piping, and more importantly, this leak
detector has great performance in today’s flexible pipe. |
|
|
|
Shortest Leak Detector Profile |
|
The 99 series leak detectors are the lowest profile detectors
available today. |
|
|
|
99 LD-2200\75 for Slow-Flow Problems with 3/4 or 1/3 hp
Submersibles |
|
The 99 LD-2200 allows more flow than any other leak detector
available. When the 99 LD-2200 is used with a 3/4 hp submersible and seven or
more nozzles, pressure in the line may fall below the pressure necessary to keep
the leak detector open. The same is true for 1/3 hp submersibles if 5 nozzles
are available for fueling. Several factors influence leak detector reset besides
available nozzles, including: burial depth, pipe size and the pump/motor
performance. If your 99 LD-2200 line leak detector is resetting when most or all
the nozzles are open, the
Vmι
99 LD-2200\75 will compensate for pressure drop at the leak detector. The 99
LD-2200\75 meets all specifications of the 99 LD-2200 and is covered by the
third party certification of the 99 LD-2200 as there is no change in function
except flow. The hex portion of the 99 LD-2200\75 is painted green. |
|
|
Technical Specifications 99
LD-2200 |
|
|
|
Fuels: |
|
|
● |
Gasoline, 100% methanol*,
100% ethanol*, up to 15% MTBE |
|
|
● |
Any combination of the above |
|
|
● |
#1 or #2 diesel, kerosene,
Jet A* or JP-4*, AV Gas*
and Biodiesel* (all blends). |
|
|
|
|
| |
*
|
When used
with Biodiesel, any alcohol fuel concentration
above 20%, Jet A, JP-4 or AV Gas, order part #
LD2-SSVS for stainless steel
fittings and stainless steel vent tubing.
For chemical applications other than listed
above, contact factory. |
| |
|
|
|
Certified to meet EPA 3 GPH @
10 PSI: |
| |
● |
Maximum Rigid
Pipeline size: 400 feet of 3.25 inch diameter
line or up to 172 gallon volume |
| |
● |
Maximum Flexible Pipeline size:
415 feet of 1.5 inch diameter line or up to 39.5
gallon volume |
|
|
|
|
|
U.L. Recognized Containment
Housing: |
| |
● |
For pump pressures
through 50 PSI |
| |
● |
Schedule 40 cast
iron with zinc phosphate protection |
| |
● |
Externally finished
with oven baked powder coat |
|
|
|
|
|
Seals: |
| |
● |
Piston / Poppet:
Teflon, stainless steel spring energized |
| |
● |
O Rings: U.L.
Approved V9702-Viton Type B Fluorocarbon |
|
|
|
|
|
Metering Pin and Poppet: |
| |
● |
17-4 Stainless Steel |
|
|
|
|
|
Misc. Component
Specification: |
| |
● |
2011-T3 Aluminum, anodized |
| |
● |
6061-T6 Aluminum,
anodized |
| |
● |
1026 cold roll
steel, chrome plated |
| |
● |
Acetron GP |
| |
|
|
|
Reverse Ratio Piston-Poppet
One-Way Poppet Flow-Path |
| |
|
|
|
For Installation with
variable or non-variable speed turbines.
Vent line must be unobstructed, leak tight and
connected to headspace of tank, not to be
subjected to pressure or vacuum.
Can be installed in submersible pump or leak
detector Adapter Tee, Part # LD99-5040 |
|
|
|
|
|
|
|
|
Press Image for
a Larger View |
|
|
NOTE: PLEASE READ THE FOLLOWING |
|
|
|
The 99 LD-2200
is the best value in leak detection available in its price
range. The One-Way Poppet and other enhancements provide
superior line leak detection performance. With the technical
enhancements outlined, this leak detector has significantly
enhanced capability to dampen the effects of hydraulic shock and
pump turbulence. |
|
|
|
THIS LEAK
DETECTOR, DESPITE ALL ENHANCEMENTS DESCRIBED, is
dependent on the proper operation and function of the pump check
valve and components of the functional element of the
submersible pump. |
|
|
|
A leaking check
valve, a defective submersible pressure relief or defective
bypass valve allows product to leave the line, reduce line
pressure, resetting the leak detector. Line pressure loss and/or
thermal contraction will cause vapor pockets to form. This
increases the length of time it takes for the leak detector to
open to full flow. |
|
|
|
THE 99 LD-2000 IS
THE ONLY 2" LEAK DETECTOR ON THE MARKET CAPABLE OF HOLDING LINE
PRESSURE AFTER THE PUMP IS OFF, WITH THE ABOVE DESCRIBED FIELD
PROBLEMS. |
|
|
|
THE 99 LD-2000
HAS A HIGHER LEVEL OF PERFORMANCE OVER A BROADER RANGE OF BURIAL
DEPTH, LINE LENGTH AND TYPE. IF SITE SPECIFIC PROBLEMS OCCUR,
THE 99 LD-2000 SHOULD BE INSTALLED. |
|
|
|
|
Click
Here For Installation Instructions |
| |